Sigenergy

Sigen Hybrid Inverter 5.0-25.0 kW Three Phase

Model range: 5.0 TP / 10.0 TP / 15.0 TP / 25.0 TP

4 pack sizes

Sigenergy Sigen Hybrid Inverter three-phase Australia (5.0–25.0 kW), battery-ready for SigenStor BAT 5.0/8.0.

InverterBattery-readyThree-phaseBusiness

At a glance

Best for

Three-phase homes and business buildings planning solar or battery integration

Standout

Inverter output is around 5–25, which helps match solar and load needs.

Watch out for

Check whether your site uses three-phase power before shortlisting this option.

Key specifications

A quick snapshot of the family. Compare module counts and capacity in the table below.

Dimensions (W × H × D)

700 × 300 × 283 mm

Output power

5–25

This affects how much power the system can deliver at one time.

Power phase

Three phase

Three-phase products are more common in larger homes and many business buildings.

Ip Rating

IP66

Compare pack sizes

Capacity, voltage, and power rise as you stack more modules. Specs that stay the same on every size are listed underneath.

Numbers that change with size.

Swipe for more sizes

Spec5.0 TP10.0 TP15.0 TP25.0 TP
Max. PV powerW8000160002400040000
Number of MPP trackers2233
Nominal output powerW500099991500025000
Max. output apparent powerVA550027500
Nominal output currentA7.614.421.738.0
Max. output currentA8.441.8
Off-grid peak output power (10 seconds)W7500150002250030000
Off-grid peak output current (10 seconds)A11.422.834.245.5

The same on every size

Max. DC input voltage
1100 V
Nominal DC input voltage
600 V
Start-up voltage
180 V
MPPT voltage range
160 ~ 1000 V
Number of PV strings per MPPT
2
Max. input current per MPPT
16 A
Max. short-circuit current per MPPT
20 A
Nominal output voltage
380 / 400 V
Nominal grid frequency
50 / 60 Hz
Power factor
0.8 leading ~ 0.8 lagging
Total current harmonic distortion
THDi < 2%
Max. efficiency
98.0%
European efficiency
97.4%
Compatible battery module
SigenStor BAT 5.0 / 8.0
Battery module voltage range
600 ~ 900 V
Number of modules per controller
1 ~ 6 pcs
Off-grid nominal output voltage
380 / 400 V
Safety protection feature
DC ground fault protection, Arc fault circuit interrupter, DC reverse polarity protection, Insulation monitoring, Residual current monitoring, Type II DC/AC surge protection, Anti-islanding protection, AC overcurrent/overvoltage/short-circuit protection
Dimensions (W / H / D)
700 / 300 / 283 mm
Weight
36 kg
Storage temperature range
-40 ~ 70 °C
Operating temperature range
-30 ~ 60 °C
Relative humidity range
0% ~ 95%
Max. operating altitude
4000 m
Cooling
Smart air cooling
Installation method
Wall-mounted
Ingress protection rating
IP66
Communication
WLAN / Fast Ethernet / RS485 / Sigen CommMod (4G/3G/2G)
Standard Compliance
IEC/EN 62109-1, IEC/EN 62109-2, IEC/EN 62477, IEC/EN 61000-6-1, IEC/EN 61000-6-2