Huawei

SUN2000-5-12K-MAP0

Model range: SUN2000-5K-MAP0 / SUN2000-6K-MAP0 / SUN2000-8K-MAP0 / SUN2000-10K-MAP0 / SUN2000-12K-MAP0

5 pack sizes

Huawei inverter SUN2000-5-12K-MAP0 (5-12 kW class).

InverterBattery-readyThree-phaseBusiness

At a glance

Best for

Three-phase homes and business buildings planning solar or battery integration

Standout

Inverter output is around 5-12, which helps match solar and load needs.

Watch out for

Check whether your site uses three-phase power before shortlisting this option.

Key specifications

A quick snapshot of the family. Compare module counts and capacity in the table below.

Output power

5-12

This affects how much power the system can deliver at one time.

Power phase

Single and three phase

Three-phase products are more common in larger homes and many business buildings.

Ip Rating

IP66

Compare pack sizes

Capacity, voltage, and power rise as you stack more modules. Specs that stay the same on every size are listed underneath.

Numbers that change with size.

Swipe for more sizes

Spec5K-MAP06K-MAP08K-MAP010K-MAP012K-MAP0
Max. efficiency%98.498.698.698.698.6
European weighted efficiency%97.597.798.098.198.2
Recommended max. PV powerWp9,00011,00014,60018,00022,000
Max. discharging powerW5,5006,6008,80011,00012,000
Rated output power (On Grid)W5,0006,0008,00010,00012,000
Max. apparent powerVA5,5006,6008,80011,00013,200
Max. output currentA8.310.013.316.720.2
Rated output power (Off Grid)W5,0006,0008,00010,00012,000

The same on every size

Max. input voltage
1,100 V
Operating voltage range
160 - 1,000 V
Startup voltage
160 V
Rated input voltage
600 V
Max. input current per MPPT
16 A
Max. short-circuit current
22 A
Number of MPP trackers
2
Max. input per MPP tracker
1
Compatible battery
LUNA2000-5/10/15-S0 / LUNA2000-7/14/21-S1
Battery operating voltage range
600 ~ 980 V
Max. operating current
20 A
Max. charging power
12,000 W
Grid connection
Three-phase
Rated output voltage (On Grid)
220 V AC/380 V AC, 230 V AC/400 V AC, 240 V AC/415 V AC 3W/N + PE
Overload capability
110 %
Rated AC grid frequency
50/60 Hz
Adjustable power factor
0.8 leading ... 0.8 lagging
Max. total harmonic distortion
≤ 3 %
Compatible backup device
SmartGuard-63A-T0 (3 phase)
Rated output voltage (Off Grid)
220 V AC/380 V AC, 230 V AC/400 V AC, 240 V AC/415 V AC 3W/N + PE
110% overload
Continuous
150% overload
5 min (3-phase) / 5 min (Single-phase)
200% overload
1 min (3-phase) / 5 min (Single-phase)
Automatic switchover time
≤ 20 ms (with SmartGuard-63A-T0)
Asymmetric load
Yes, supports 100% three-phase asymmetric load
Input-side disconnection device
Yes
Anti-islanding protection
Yes
DC reverse polarity protection
Yes
Insulation detection
Yes
DC surge protection
Yes, compatible with TYPE II protection class according to EN/IEC 61643-11
AC surge protection
Yes, compatible with TYPE II protection class according to EN/IEC 61643-11
Residual current detection
Yes
AC overcurrent protection
Yes
AC short-circuit protection
Yes
AC overvoltage protection
Yes
Arc fault protection
Yes
Connector temperature detection
Yes (PV & Battery connectors)
Ripple receiver control
Yes
Battery charging from grid
Yes
Operating temperature range
–25°C - +60°C (–13°F - +140°F)
Relative operating humidity
0 - 100 % RH
Max. operating altitude
4,000 m
Cooling
Natural convection
Noise
≤ 29 dB
Display
LED Indicators; Integrated WLAN + FusionSolar APP
Communication
RS485; WLAN / Ethernet via Smart Dongle-WLAN-FE (Optional); 4G/3G/2G via Smart Dongle-4G (Optional); EMMA (Optional)
Weight (incl. mounting brackets)
21 kg
Dimensions (incl. mounting brackets)
490 mm x 460 mm x 130 mm
IP rating
IP66
Nighttime power
< 5.5 W
DC MBUS compatible optimizer
SUN2000-450W-P2, SUN2000-600W-P
Safety
EN/IEC62109-1, EN/IEC62109-2
Grid connection standards
IEC61727, IEC62116, MEA/PEA, G99, Philippine Grid Code Resolution No. 07, NRS 097-2-1, EN50549-1, VDE4105, UTE15-712-1/VFR 2019, UNE217002, NTS631, RD244(UNE217001), PPDS, ROGA, TOR Erzeuger, CEI 0-21:2020-12 V1, C10/C11